• 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction
  • 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction
  • 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction
  • 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction
  • 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction
  • 2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction

2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction

After-sales Service: on Line
Warranty: One Year
Max Diameter of Workpiece: >3200mm
Mass Scope of Workpiece: Customizable
Type: Motor Parameter Testing
Maxcapacity: >1000KN
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
Raw-Materials Traceability
The supplier has traceability identification of raw materials
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (21)

Basic Info.

Model NO.
CN
Accuracy Grade
0.5
Load Way
Mechanical Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Power Test Error
Not More Than 0.2%
Full Pressure, Static Pressure Range
0-50000PA
Flow Range
0-10000m3/N
Torque Range
0-100.0 N.M
Speed Range
0-5000rpm
Power Range
0-55kw
Flow Accuracy
Positive and Negative 2%
Torque Accuracy
Positive and Negative 0.5%
Speed Accuracy
Positive and Negative 0.2%
Power Accuracy
Positive and Negative 0.5%
Transport Package
Dust-Free Packaging + Sturdy Wooden Crates
Specification
customisable
Trademark
Changniu Technology
Origin
Hangzhou, China
Production Capacity
50pieces/Year

Product Description

 
Test model
Centrifugal fans, axial fans, air handling units, etc
Test items
Fan air volume, fan speed, torque, power, rated point air pressure measurement, rated point air volume measurement, as well as output power, wind pressure and various characteristic curve tests.
 
2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction

The wind turbine characteristic curve test is carried out on the test bench. All project test programs are collected and tested by the computer, and the test results are displayed. The computer system adopts WINDOWS operating system, with beautiful man-machine interface, which can collect, record, store and display the test data and results of each project, print the test data and characteristic curves, and provide computer software with easy operation, flexible adjustment and intuitive and clear man-machine interface. The system adopts the manual test working mode, and uses the frequency conversion motor and frequency converter for speed regulation test, and the test bench test is according to GB/T1236-2000 "Performance Test of Standardized Air Duct for Industrial Ventilator".
The test device for technical indicators of the test project includes two categories: air duct test and air chamber test. According to the convention, the fan with higher pressure is tested by the air duct test bench, and the fan with lower pressure is tested by the air chamber test bench, which can be divided into four types according to the GB/T1236-2000 standard, namely type A, type B, type C and type D. The fan and the motor, torque and speed sensor are installed on a cast iron test platform, and the air inlet at one end manufactured according to the GB/T1236 standard is adjusted by the air inlet with a damper, and the motor adds the rated voltage to make the fan blow, and the computer controls the change of the air inlet plate of the equalizing box to the stalled rotor, and changes uniformly 16 times. Measure the wind pressure H and input power P1 at each point, and calculate the output power PS and efficiency Eff. Test method. II. pF=f(Q)     PZ=f(Q)    Eff=f(Q)   n=f(Q)
 
parameter table range  Accuracy
Full pressure, static pressure 0-50000Pa ±1%
Flow 0-10000m3/n ±2%
Torque 0-100.0 N.m ±0.5%
Speed 0-5000RPM ±0.2%
Power 0-55KW ±0.5%
 
  2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction2kw or Less Small Fan Air Volume Test Machine Energy Saving and Consumption Reduction