Motor performance test bench test system consists of test power supply, power switch screen cabinet, signal sensing device and power measurement equipment, automated test measurement unit and control console and AC motor test software system, database system and other components.
Measurement mode: using frequency conversion power analyzer measurement
Measuring cabinet is equipped with inverter power sensor, adopting front-end digital technology and fiber-optic transmission in the middle to transmit the digital signal to the digital host to complete the signal processing and display the real-time data, real-time waveform, harmonic analysis and other parameters.
Control mode: using the upper computer control
PC + host computer control mode, flexible control mode, can be customized according to user requirements, modification, control system performance is stable, good system scalability.
Operation mode: manual operation and automatic operation coexist.
In order to avoid the microcomputer failure to affect the test work, manual control (panel button operation) and automatic control (computer keyboard/mouse operation) coexist, inconvenient to use automatic control or microcomputer failure, you can use manual operation to test.
Technical Parameters:
Design Principles
Reliability, safety, economy, practicability, operability and maintainability are the design principles, taking into account the advancement at the same time.
Scope of application
It is suitable for factory and maintenance test of three-phase asynchronous motors with rated voltage 380V, 660V, 1140V, 3300V, 6000V, 10000V and rated power 1 ~ 15000kW.
Operating conditions
The rated working temperature of the central control room is +20ºC, the permissible variation range is 0ºC ~ 45ºC, and the relative humidity of the air does not exceed 85%.
The central control room is far away from electromagnetic field interference and mechanical vibration, and corrosive gas erosion is avoided.
The ambient temperature of the screen cabinet area and equipment area is -5ºC~+45ºC, and the relative humidity of the air does not exceed 80% at +40ºC and 85% at +25ºC.
There shall be no excessive dust, acid, salt, corrosive and explosive gases in the air.
Installation altitude not exceeding 1000m.
Test items
Users can choose the following test items according to their requirements:
Ambient temperature measurement
Insulation resistance measurement
Direct current resistance measurement (calculation of three-phase resistance imbalance)
Working frequency withstand voltage test
Turn-to-turn withstand voltage test
No-load test (calculation of three-phase current imbalance)
Blocking test
Load test
Efficiency test
Temperature rise test.
The system completes the measurement and calculation of voltage measurement, current measurement, power factor measurement, power measurement, reactive power measurement, efficiency measurement, frequency measurement, output torque, output speed, output power, temperature rise and so on.
Main technical parameters:
No load, plugging, loading test, temperature rise:
Current measurement accuracy: 0.2%FS±3d
Voltage measurement accuracy: 0.2%FS±3d
Power measurement accuracy: 0.5%FS±3d
Current imbalance calculation: 0.1%FS±3d
Temperature measurement accuracy: 0.5%±2d
Speed measurement accuracy: 0.2%FS±3d
Torque measurement accuracy: 0.2%FS±3d
Industrial frequency withstand voltage test
High-voltage voltage: 0~30000V adjustable
High-voltage current: 0~3000mA
Turn-to-turn impact withstand voltage test: 0~30,000V adjustable
Turn-to-turn impact withstand voltage test:
Peak voltage: <30000V, adjustable
Wave front time: < 0.5us, adjustable
Insulation resistance measurement
Measuring range: <1000MΩ
Measuring accuracy: 5%FS±5d
DC resistance measurement:
Measuring current: <10A
Measuring resistance: 0~200Ω
Minimum resolution: 1uΩ
Resistance unbalance calculation: 0.1%FS±3d
Measurement accuracy: 0.2%FS±3d